





ROGER MC16-3
- The MC16 is a multi-door physical access and building automation controller dedicated to RACS 5 system. Depending on the version, it allows to control up to 16 two-way doors and 32 automation nodes (states). MC16 can be integrated with intruder alarm system by means of IO lines. The MC16 can be used as data collector device for time and attendance reporting systems. Generally, controller was designed to operate with MCT (RS485) series readers, nevertheless it can work with Wiegand and RACS CLK/DTA readers as well. The RS485 communication bus allows free cable topology (e.g. three, star and combination of them) and accepts any type of signal cables.Controller is equipped with Ethernet interface which is used for system configuration and management. System is managed by VISO client-server Windows application operating with Microsoft SQL Server or Microsoft SQL Server Compact database. Communication between PC and controller is fully encrypted using AES-128-CBC method and can be conducted either in LAN or WAN computer networks. Usually, system configuration takes less than one minute and doesn’t depend on number of controllers which is theoretically unlimited.






ROGER MC16-2
- The MC16 is a multi-door physical access and building automation controller dedicated to RACS 5 system. Depending on the version, it allows to control up to 16 two-way doors and 32 automation nodes (states). MC16 can be integrated with intruder alarm system by means of IO lines. The MC16 can be used as data collector device for time and attendance reporting systems. Generally, controller was designed to operate with MCT (RS485) series readers, nevertheless it can work with Wiegand and RACS CLK/DTA readers as well. The RS485 communication bus allows free cable topology (e.g. three, star and combination of them) and accepts any type of signal cables.Controller is equipped with Ethernet interface which is used for system configuration and management. System is managed by VISO client-server Windows application operating with Microsoft SQL Server or Microsoft SQL Server Compact database. Communication between PC and controller is fully encrypted using AES-128-CBC method and can be conducted either in LAN or WAN computer networks. Usually, system configuration takes less than one minute and doesn’t depend on number of controllers which is theoretically unlimited.






ROGER MC16-1
- The MC16 is a multi-door physical access and building automation controller dedicated to RACS 5 system. Depending on the version, it allows to control up to 16 two-way doors and 32 automation nodes (states). MC16 can be integrated with intruder alarm system by means of IO lines. The MC16 can be used as data collector device for time and attendance reporting systems. Generally, controller was designed to operate with MCT (RS485) series readers, nevertheless it can work with Wiegand and RACS CLK/DTA readers as well. The RS485 communication bus allows free cable topology (e.g. three, star and combination of them) and accepts any type of signal cables.Controller is equipped with Ethernet interface which is used for system configuration and management. System is managed by VISO client-server Windows application operating with Microsoft SQL Server or Microsoft SQL Server Compact database. Communication between PC and controller is fully encrypted using AES-128-CBC method and can be conducted either in LAN or WAN computer networks. Usually, system configuration takes less than one minute and doesn’t depend on number of controllers which is theoretically unlimited.






Controller ROGER MC16-LRC-64
- Locker controller (up to 64), RACS 5, 8192 users, 8 mln. events.






Controller ROGER MC16-LRC-32
- Locker controller (up to 32), RACS 5, 8192 users, 8 mln. events.






Controller ROGER MC16-LRC-16
- Locker controller (up to 16), RACS 5, 8192 users, 8 mln. events.






Plastic enclosure ROGER PR402DR-12VDC
- Controller in DIN 35mm rail plastic enclosure
- The access controller for single door
- Mounted inside plastic enclosure dedicated to installation on 35mm DIN rail
- Operating with AC supply, equipped with built in 1.5 A buffered power supply
- Eequires connection of external proximity readers






ROGER MC16-4
- The MC16 is a multi-door physical access and building automation controller dedicated to RACS 5 system. Depending on the version, it allows to control up to 16 two-way doors and 32 automation nodes (states). MC16 can be integrated with intruder alarm system by means of IO lines. The MC16 can be used as data collector device for time and attendance reporting systems. Generally, controller was designed to operate with MCT (RS485) series readers, nevertheless it can work with Wiegand and RACS CLK/DTA readers as well. The RS485 communication bus allows free cable topology (e.g. three, star and combination of them) and accepts any type of signal cables.Controller is equipped with Ethernet interface which is used for system configuration and management. System is managed by VISO client-server Windows application operating with Microsoft SQL Server or Microsoft SQL Server Compact database. Communication between PC and controller is fully encrypted using AES-128-CBC method and can be conducted either in LAN or WAN computer networks. Usually, system configuration takes less than one minute and doesn’t depend on number of controllers which is theoretically unlimited.






ROGER PR622-G
- Outdoor access controller
- Built-in EM 125 kHz proximity reader
- Screw terminals
- Optionally can be installed on Ø 60mm flush box
- Dark grey enclosure






Plastic enclosure ROGER PR402DR
- PR402DR – controller in DIN 35mm rail plastic enclosure
- The access controller for single door
- Mounted inside plastic enclosure dedicated to installation on 35mm DIN rail
- Operating with AC supply, equipped with built in 1.5 A buffered power supply
- Eequires connection of external proximity readers






Electronic module ROGER PR102DR-BRD
- PR102DR-BRD – electronic module of controller without enclosure
- Single door access controller
- Adapted to connection of two External PRT series (Roger) readers
- 12 VDC power supply
- Mounted inside plastic enclosure dedicated to installation on 35mm DIN rail
- PR102DR is the simplest device within advanced series controllers and it offers the most essential functions, including event buffer and real time clock






Plastic enclosure ROGER PR102DR
- PR102DR – controller in DIN 35mm rail plastic enclosure
- Single door access controller
- Adapted to connection of two External PRT series (Roger) readers
- 12 VDC power supply
- Mounted inside plastic enclosure dedicated to installation on 35mm DIN rail
- PR102DR is the simplest device within advanced series controllers and it offers the most essential functions, including event buffer and real time clock






ROGER PR311SE-BK-G
- Outdoor access controller
- Built-in EM 125 kHz proximity reader
- Connecting cable 0.5 m
- Without keypad






ROGER PR311SE-G
- Outdoor access controller
- Built-in EM 125 kHz proximity reader
- Connecting cable 0.5 m
- Silicone keypad with backlight
- Two function keys
- Dark grey case






ROGER CPR32-NET-BRD
- CPR32-NET-BRD network controller expands functionality of RACS 4 system and due to the built-in Ethernet interface allows for management of the access control system through LAN or WAN network.
- The most important features provided by CPR32-NET-BRD are: centralized event buffer, centralized clock and calendar, global anti-passback and connection of controllers in concurrently armed and disarmed alarm zones.
- Additionally, CPR32-NET-BRD offers software integration with Integra series intruder alarm panels (SATEL) and management of 16 wireless Sallis door locks (SALTO).






ROGER PR621-G
- Outdoor access controller
- Built-in EM 125 kHz proximity reader
- Bolted contacts
- Mountable directly in a 60 mm gang box
- Dark grey case






ROGER PR611-G
- Outdoor access controller
- Built-in EM 125 kHz proximity reader
- Bolted contacts
- Silicone keypad with backlight
- Mountable directly in a 60 mmgang box
- Dark grey case






ROGER CPR32-SE
- CPR32-SE Network Controller is an optional Roger Access Control System (RACS) component.
- Using CPR32-SE in the system expands its functionality with specific features.
- When used with PRxx1 series controllers CPR32-SE allows for logging events and defining time-based access rights.
- In case of PRxx2 series controllers, CPR32-SE provides a global anti-passback feature and grouping controllers into so called Alarm Zones.






ROGER MC16-3
- The MC16 is a multi-door physical access and building automation controller dedicated to RACS 5 system. Depending on the version, it allows to control up to 16 two-way doors and 32 automation nodes (states). MC16 can be integrated with intruder alarm system by means of IO lines. The MC16 can be used as data collector device for time and attendance reporting systems. Generally, controller was designed to operate with MCT (RS485) series readers, nevertheless it can work with Wiegand and RACS CLK/DTA readers as well. The RS485 communication bus allows free cable topology (e.g. three, star and combination of them) and accepts any type of signal cables.Controller is equipped with Ethernet interface which is used for system configuration and management. System is managed by VISO client-server Windows application operating with Microsoft SQL Server or Microsoft SQL Server Compact database. Communication between PC and controller is fully encrypted using AES-128-CBC method and can be conducted either in LAN or WAN computer networks. Usually, system configuration takes less than one minute and doesn’t depend on number of controllers which is theoretically unlimited.






ROGER MC16-2
- The MC16 is a multi-door physical access and building automation controller dedicated to RACS 5 system. Depending on the version, it allows to control up to 16 two-way doors and 32 automation nodes (states). MC16 can be integrated with intruder alarm system by means of IO lines. The MC16 can be used as data collector device for time and attendance reporting systems. Generally, controller was designed to operate with MCT (RS485) series readers, nevertheless it can work with Wiegand and RACS CLK/DTA readers as well. The RS485 communication bus allows free cable topology (e.g. three, star and combination of them) and accepts any type of signal cables.Controller is equipped with Ethernet interface which is used for system configuration and management. System is managed by VISO client-server Windows application operating with Microsoft SQL Server or Microsoft SQL Server Compact database. Communication between PC and controller is fully encrypted using AES-128-CBC method and can be conducted either in LAN or WAN computer networks. Usually, system configuration takes less than one minute and doesn’t depend on number of controllers which is theoretically unlimited.






ROGER MC16-1
- The MC16 is a multi-door physical access and building automation controller dedicated to RACS 5 system. Depending on the version, it allows to control up to 16 two-way doors and 32 automation nodes (states). MC16 can be integrated with intruder alarm system by means of IO lines. The MC16 can be used as data collector device for time and attendance reporting systems. Generally, controller was designed to operate with MCT (RS485) series readers, nevertheless it can work with Wiegand and RACS CLK/DTA readers as well. The RS485 communication bus allows free cable topology (e.g. three, star and combination of them) and accepts any type of signal cables.Controller is equipped with Ethernet interface which is used for system configuration and management. System is managed by VISO client-server Windows application operating with Microsoft SQL Server or Microsoft SQL Server Compact database. Communication between PC and controller is fully encrypted using AES-128-CBC method and can be conducted either in LAN or WAN computer networks. Usually, system configuration takes less than one minute and doesn’t depend on number of controllers which is theoretically unlimited.
























Plastic enclosure ROGER PR402DR-12VDC
- Controller in DIN 35mm rail plastic enclosure
- The access controller for single door
- Mounted inside plastic enclosure dedicated to installation on 35mm DIN rail
- Operating with AC supply, equipped with built in 1.5 A buffered power supply
- Eequires connection of external proximity readers






ROGER MC16-4
- The MC16 is a multi-door physical access and building automation controller dedicated to RACS 5 system. Depending on the version, it allows to control up to 16 two-way doors and 32 automation nodes (states). MC16 can be integrated with intruder alarm system by means of IO lines. The MC16 can be used as data collector device for time and attendance reporting systems. Generally, controller was designed to operate with MCT (RS485) series readers, nevertheless it can work with Wiegand and RACS CLK/DTA readers as well. The RS485 communication bus allows free cable topology (e.g. three, star and combination of them) and accepts any type of signal cables.Controller is equipped with Ethernet interface which is used for system configuration and management. System is managed by VISO client-server Windows application operating with Microsoft SQL Server or Microsoft SQL Server Compact database. Communication between PC and controller is fully encrypted using AES-128-CBC method and can be conducted either in LAN or WAN computer networks. Usually, system configuration takes less than one minute and doesn’t depend on number of controllers which is theoretically unlimited.






ROGER PR622-G
- Outdoor access controller
- Built-in EM 125 kHz proximity reader
- Screw terminals
- Optionally can be installed on Ø 60mm flush box
- Dark grey enclosure






Plastic enclosure ROGER PR402DR
- PR402DR – controller in DIN 35mm rail plastic enclosure
- The access controller for single door
- Mounted inside plastic enclosure dedicated to installation on 35mm DIN rail
- Operating with AC supply, equipped with built in 1.5 A buffered power supply
- Eequires connection of external proximity readers






Electronic module ROGER PR102DR-BRD
- PR102DR-BRD – electronic module of controller without enclosure
- Single door access controller
- Adapted to connection of two External PRT series (Roger) readers
- 12 VDC power supply
- Mounted inside plastic enclosure dedicated to installation on 35mm DIN rail
- PR102DR is the simplest device within advanced series controllers and it offers the most essential functions, including event buffer and real time clock






Plastic enclosure ROGER PR102DR
- PR102DR – controller in DIN 35mm rail plastic enclosure
- Single door access controller
- Adapted to connection of two External PRT series (Roger) readers
- 12 VDC power supply
- Mounted inside plastic enclosure dedicated to installation on 35mm DIN rail
- PR102DR is the simplest device within advanced series controllers and it offers the most essential functions, including event buffer and real time clock






ROGER PR311SE-BK-G
- Outdoor access controller
- Built-in EM 125 kHz proximity reader
- Connecting cable 0.5 m
- Without keypad






ROGER PR311SE-G
- Outdoor access controller
- Built-in EM 125 kHz proximity reader
- Connecting cable 0.5 m
- Silicone keypad with backlight
- Two function keys
- Dark grey case






ROGER CPR32-NET-BRD
- CPR32-NET-BRD network controller expands functionality of RACS 4 system and due to the built-in Ethernet interface allows for management of the access control system through LAN or WAN network.
- The most important features provided by CPR32-NET-BRD are: centralized event buffer, centralized clock and calendar, global anti-passback and connection of controllers in concurrently armed and disarmed alarm zones.
- Additionally, CPR32-NET-BRD offers software integration with Integra series intruder alarm panels (SATEL) and management of 16 wireless Sallis door locks (SALTO).






ROGER PR621-G
- Outdoor access controller
- Built-in EM 125 kHz proximity reader
- Bolted contacts
- Mountable directly in a 60 mm gang box
- Dark grey case






ROGER PR611-G
- Outdoor access controller
- Built-in EM 125 kHz proximity reader
- Bolted contacts
- Silicone keypad with backlight
- Mountable directly in a 60 mmgang box
- Dark grey case






ROGER CPR32-SE
- CPR32-SE Network Controller is an optional Roger Access Control System (RACS) component.
- Using CPR32-SE in the system expands its functionality with specific features.
- When used with PRxx1 series controllers CPR32-SE allows for logging events and defining time-based access rights.
- In case of PRxx2 series controllers, CPR32-SE provides a global anti-passback feature and grouping controllers into so called Alarm Zones.






ROGER MC16-3
- The MC16 is a multi-door physical access and building automation controller dedicated to RACS 5 system. Depending on the version, it allows to control up to 16 two-way doors and 32 automation nodes (states). MC16 can be integrated with intruder alarm system by means of IO lines. The MC16 can be used as data collector device for time and attendance reporting systems. Generally, controller was designed to operate with MCT (RS485) series readers, nevertheless it can work with Wiegand and RACS CLK/DTA readers as well. The RS485 communication bus allows free cable topology (e.g. three, star and combination of them) and accepts any type of signal cables.Controller is equipped with Ethernet interface which is used for system configuration and management. System is managed by VISO client-server Windows application operating with Microsoft SQL Server or Microsoft SQL Server Compact database. Communication between PC and controller is fully encrypted using AES-128-CBC method and can be conducted either in LAN or WAN computer networks. Usually, system configuration takes less than one minute and doesn’t depend on number of controllers which is theoretically unlimited.






ROGER MC16-2
- The MC16 is a multi-door physical access and building automation controller dedicated to RACS 5 system. Depending on the version, it allows to control up to 16 two-way doors and 32 automation nodes (states). MC16 can be integrated with intruder alarm system by means of IO lines. The MC16 can be used as data collector device for time and attendance reporting systems. Generally, controller was designed to operate with MCT (RS485) series readers, nevertheless it can work with Wiegand and RACS CLK/DTA readers as well. The RS485 communication bus allows free cable topology (e.g. three, star and combination of them) and accepts any type of signal cables.Controller is equipped with Ethernet interface which is used for system configuration and management. System is managed by VISO client-server Windows application operating with Microsoft SQL Server or Microsoft SQL Server Compact database. Communication between PC and controller is fully encrypted using AES-128-CBC method and can be conducted either in LAN or WAN computer networks. Usually, system configuration takes less than one minute and doesn’t depend on number of controllers which is theoretically unlimited.






ROGER MC16-1
- The MC16 is a multi-door physical access and building automation controller dedicated to RACS 5 system. Depending on the version, it allows to control up to 16 two-way doors and 32 automation nodes (states). MC16 can be integrated with intruder alarm system by means of IO lines. The MC16 can be used as data collector device for time and attendance reporting systems. Generally, controller was designed to operate with MCT (RS485) series readers, nevertheless it can work with Wiegand and RACS CLK/DTA readers as well. The RS485 communication bus allows free cable topology (e.g. three, star and combination of them) and accepts any type of signal cables.Controller is equipped with Ethernet interface which is used for system configuration and management. System is managed by VISO client-server Windows application operating with Microsoft SQL Server or Microsoft SQL Server Compact database. Communication between PC and controller is fully encrypted using AES-128-CBC method and can be conducted either in LAN or WAN computer networks. Usually, system configuration takes less than one minute and doesn’t depend on number of controllers which is theoretically unlimited.
























Plastic enclosure ROGER PR402DR-12VDC
- Controller in DIN 35mm rail plastic enclosure
- The access controller for single door
- Mounted inside plastic enclosure dedicated to installation on 35mm DIN rail
- Operating with AC supply, equipped with built in 1.5 A buffered power supply
- Eequires connection of external proximity readers






ROGER MC16-4
- The MC16 is a multi-door physical access and building automation controller dedicated to RACS 5 system. Depending on the version, it allows to control up to 16 two-way doors and 32 automation nodes (states). MC16 can be integrated with intruder alarm system by means of IO lines. The MC16 can be used as data collector device for time and attendance reporting systems. Generally, controller was designed to operate with MCT (RS485) series readers, nevertheless it can work with Wiegand and RACS CLK/DTA readers as well. The RS485 communication bus allows free cable topology (e.g. three, star and combination of them) and accepts any type of signal cables.Controller is equipped with Ethernet interface which is used for system configuration and management. System is managed by VISO client-server Windows application operating with Microsoft SQL Server or Microsoft SQL Server Compact database. Communication between PC and controller is fully encrypted using AES-128-CBC method and can be conducted either in LAN or WAN computer networks. Usually, system configuration takes less than one minute and doesn’t depend on number of controllers which is theoretically unlimited.






ROGER PR622-G
- Outdoor access controller
- Built-in EM 125 kHz proximity reader
- Screw terminals
- Optionally can be installed on Ø 60mm flush box
- Dark grey enclosure






Plastic enclosure ROGER PR402DR
- PR402DR – controller in DIN 35mm rail plastic enclosure
- The access controller for single door
- Mounted inside plastic enclosure dedicated to installation on 35mm DIN rail
- Operating with AC supply, equipped with built in 1.5 A buffered power supply
- Eequires connection of external proximity readers






Electronic module ROGER PR102DR-BRD
- PR102DR-BRD – electronic module of controller without enclosure
- Single door access controller
- Adapted to connection of two External PRT series (Roger) readers
- 12 VDC power supply
- Mounted inside plastic enclosure dedicated to installation on 35mm DIN rail
- PR102DR is the simplest device within advanced series controllers and it offers the most essential functions, including event buffer and real time clock






Plastic enclosure ROGER PR102DR
- PR102DR – controller in DIN 35mm rail plastic enclosure
- Single door access controller
- Adapted to connection of two External PRT series (Roger) readers
- 12 VDC power supply
- Mounted inside plastic enclosure dedicated to installation on 35mm DIN rail
- PR102DR is the simplest device within advanced series controllers and it offers the most essential functions, including event buffer and real time clock






ROGER PR311SE-BK-G
- Outdoor access controller
- Built-in EM 125 kHz proximity reader
- Connecting cable 0.5 m
- Without keypad






ROGER PR311SE-G
- Outdoor access controller
- Built-in EM 125 kHz proximity reader
- Connecting cable 0.5 m
- Silicone keypad with backlight
- Two function keys
- Dark grey case






ROGER CPR32-NET-BRD
- CPR32-NET-BRD network controller expands functionality of RACS 4 system and due to the built-in Ethernet interface allows for management of the access control system through LAN or WAN network.
- The most important features provided by CPR32-NET-BRD are: centralized event buffer, centralized clock and calendar, global anti-passback and connection of controllers in concurrently armed and disarmed alarm zones.
- Additionally, CPR32-NET-BRD offers software integration with Integra series intruder alarm panels (SATEL) and management of 16 wireless Sallis door locks (SALTO).






ROGER PR621-G
- Outdoor access controller
- Built-in EM 125 kHz proximity reader
- Bolted contacts
- Mountable directly in a 60 mm gang box
- Dark grey case






ROGER PR611-G
- Outdoor access controller
- Built-in EM 125 kHz proximity reader
- Bolted contacts
- Silicone keypad with backlight
- Mountable directly in a 60 mmgang box
- Dark grey case






ROGER CPR32-SE
- CPR32-SE Network Controller is an optional Roger Access Control System (RACS) component.
- Using CPR32-SE in the system expands its functionality with specific features.
- When used with PRxx1 series controllers CPR32-SE allows for logging events and defining time-based access rights.
- In case of PRxx2 series controllers, CPR32-SE provides a global anti-passback feature and grouping controllers into so called Alarm Zones.






ROGER MC16-3
SKU: PSKMC16-3- The MC16 is a multi-door physical access and building automation controller dedicated to RACS 5 system. Depending on the version, it allows to control up to 16 two-way doors and 32 automation nodes (states). MC16 can be integrated with intruder alarm system by means of IO lines. The MC16 can be used as data collector device for time and attendance reporting systems. Generally, controller was designed to operate with MCT (RS485) series readers, nevertheless it can work with Wiegand and RACS CLK/DTA readers as well. The RS485 communication bus allows free cable topology (e.g. three, star and combination of them) and accepts any type of signal cables.Controller is equipped with Ethernet interface which is used for system configuration and management. System is managed by VISO client-server Windows application operating with Microsoft SQL Server or Microsoft SQL Server Compact database. Communication between PC and controller is fully encrypted using AES-128-CBC method and can be conducted either in LAN or WAN computer networks. Usually, system configuration takes less than one minute and doesn’t depend on number of controllers which is theoretically unlimited.






ROGER MC16-2
SKU: PSKMC16-2- The MC16 is a multi-door physical access and building automation controller dedicated to RACS 5 system. Depending on the version, it allows to control up to 16 two-way doors and 32 automation nodes (states). MC16 can be integrated with intruder alarm system by means of IO lines. The MC16 can be used as data collector device for time and attendance reporting systems. Generally, controller was designed to operate with MCT (RS485) series readers, nevertheless it can work with Wiegand and RACS CLK/DTA readers as well. The RS485 communication bus allows free cable topology (e.g. three, star and combination of them) and accepts any type of signal cables.Controller is equipped with Ethernet interface which is used for system configuration and management. System is managed by VISO client-server Windows application operating with Microsoft SQL Server or Microsoft SQL Server Compact database. Communication between PC and controller is fully encrypted using AES-128-CBC method and can be conducted either in LAN or WAN computer networks. Usually, system configuration takes less than one minute and doesn’t depend on number of controllers which is theoretically unlimited.






ROGER MC16-1
SKU: PSKMC16-1- The MC16 is a multi-door physical access and building automation controller dedicated to RACS 5 system. Depending on the version, it allows to control up to 16 two-way doors and 32 automation nodes (states). MC16 can be integrated with intruder alarm system by means of IO lines. The MC16 can be used as data collector device for time and attendance reporting systems. Generally, controller was designed to operate with MCT (RS485) series readers, nevertheless it can work with Wiegand and RACS CLK/DTA readers as well. The RS485 communication bus allows free cable topology (e.g. three, star and combination of them) and accepts any type of signal cables.Controller is equipped with Ethernet interface which is used for system configuration and management. System is managed by VISO client-server Windows application operating with Microsoft SQL Server or Microsoft SQL Server Compact database. Communication between PC and controller is fully encrypted using AES-128-CBC method and can be conducted either in LAN or WAN computer networks. Usually, system configuration takes less than one minute and doesn’t depend on number of controllers which is theoretically unlimited.






Controller ROGER MC16-LRC-64
SKU: MC16-LRC-64- Locker controller (up to 64), RACS 5, 8192 users, 8 mln. events.






Controller ROGER MC16-LRC-32
SKU: MC16-LRC-32- Locker controller (up to 32), RACS 5, 8192 users, 8 mln. events.






Controller ROGER MC16-LRC-16
SKU: MC16-LRC-16- Locker controller (up to 16), RACS 5, 8192 users, 8 mln. events.






Plastic enclosure ROGER PR402DR-12VDC
SKU: PSKPR402DR12VDC- Controller in DIN 35mm rail plastic enclosure
- The access controller for single door
- Mounted inside plastic enclosure dedicated to installation on 35mm DIN rail
- Operating with AC supply, equipped with built in 1.5 A buffered power supply
- Eequires connection of external proximity readers






ROGER MC16-4
SKU: PSKMC16-4- The MC16 is a multi-door physical access and building automation controller dedicated to RACS 5 system. Depending on the version, it allows to control up to 16 two-way doors and 32 automation nodes (states). MC16 can be integrated with intruder alarm system by means of IO lines. The MC16 can be used as data collector device for time and attendance reporting systems. Generally, controller was designed to operate with MCT (RS485) series readers, nevertheless it can work with Wiegand and RACS CLK/DTA readers as well. The RS485 communication bus allows free cable topology (e.g. three, star and combination of them) and accepts any type of signal cables.Controller is equipped with Ethernet interface which is used for system configuration and management. System is managed by VISO client-server Windows application operating with Microsoft SQL Server or Microsoft SQL Server Compact database. Communication between PC and controller is fully encrypted using AES-128-CBC method and can be conducted either in LAN or WAN computer networks. Usually, system configuration takes less than one minute and doesn’t depend on number of controllers which is theoretically unlimited.






ROGER PR622-G
SKU: PSKPR622G- Outdoor access controller
- Built-in EM 125 kHz proximity reader
- Screw terminals
- Optionally can be installed on Ø 60mm flush box
- Dark grey enclosure






Plastic enclosure ROGER PR402DR
SKU: PSKPR402DR- PR402DR – controller in DIN 35mm rail plastic enclosure
- The access controller for single door
- Mounted inside plastic enclosure dedicated to installation on 35mm DIN rail
- Operating with AC supply, equipped with built in 1.5 A buffered power supply
- Eequires connection of external proximity readers






Electronic module ROGER PR102DR-BRD
SKU: PSKPR102DRBRD- PR102DR-BRD – electronic module of controller without enclosure
- Single door access controller
- Adapted to connection of two External PRT series (Roger) readers
- 12 VDC power supply
- Mounted inside plastic enclosure dedicated to installation on 35mm DIN rail
- PR102DR is the simplest device within advanced series controllers and it offers the most essential functions, including event buffer and real time clock






Plastic enclosure ROGER PR102DR
SKU: PSKPR102DR- PR102DR – controller in DIN 35mm rail plastic enclosure
- Single door access controller
- Adapted to connection of two External PRT series (Roger) readers
- 12 VDC power supply
- Mounted inside plastic enclosure dedicated to installation on 35mm DIN rail
- PR102DR is the simplest device within advanced series controllers and it offers the most essential functions, including event buffer and real time clock






ROGER PR311SE-BK-G
SKU: PSKPR311SEBKG- Outdoor access controller
- Built-in EM 125 kHz proximity reader
- Connecting cable 0.5 m
- Without keypad






ROGER PR311SE-G
SKU: PSKPR311SEG- Outdoor access controller
- Built-in EM 125 kHz proximity reader
- Connecting cable 0.5 m
- Silicone keypad with backlight
- Two function keys
- Dark grey case






ROGER CPR32-NET-BRD
SKU: PSKCPR32NET- CPR32-NET-BRD network controller expands functionality of RACS 4 system and due to the built-in Ethernet interface allows for management of the access control system through LAN or WAN network.
- The most important features provided by CPR32-NET-BRD are: centralized event buffer, centralized clock and calendar, global anti-passback and connection of controllers in concurrently armed and disarmed alarm zones.
- Additionally, CPR32-NET-BRD offers software integration with Integra series intruder alarm panels (SATEL) and management of 16 wireless Sallis door locks (SALTO).






ROGER PR621-G
SKU: PSKPR621G- Outdoor access controller
- Built-in EM 125 kHz proximity reader
- Bolted contacts
- Mountable directly in a 60 mm gang box
- Dark grey case






ROGER PR611-G
SKU: PSKPR611G- Outdoor access controller
- Built-in EM 125 kHz proximity reader
- Bolted contacts
- Silicone keypad with backlight
- Mountable directly in a 60 mmgang box
- Dark grey case






ROGER CPR32-SE
SKU: PSKCPR32-SE- CPR32-SE Network Controller is an optional Roger Access Control System (RACS) component.
- Using CPR32-SE in the system expands its functionality with specific features.
- When used with PRxx1 series controllers CPR32-SE allows for logging events and defining time-based access rights.
- In case of PRxx2 series controllers, CPR32-SE provides a global anti-passback feature and grouping controllers into so called Alarm Zones.