Aprašymas
1. PURPOSE
Non sensitive element is a part of the TRIBO-M fence protection system which is not sensitive for deformation and vibration. It is using to transmit signals between TRIBO-M unit and sensitive element or connect SE-86 with SE-86 using connection sleeves.
2. GENERAL INFORMATION
Non sensitive element max. length in one input channel of TRIBO-M processing unit is 300 meters, it can be interchange with SE-86 to NON-SE to SE-86.
Non sensitive elements isolation is not protected from the outside weather conditions so the element must be protected with plastic corrugated tube when mounted on the fence or underground.
3. LAYING OF NON SENSITIVE ELEMENT
TRIBO-M processing unit installation near the fence.
Variant where TRIBO-M processing unit installed near the fence (in security room) at distance from the protected fence were sensitive elements is mounted. In this variant with one TRIBO-M processing unit we can protect up to 600 meters of the fence. The maximum length of sensitive element and non-sensitive for one detection zone is SE-86 300 meters NON-SE 300 meters.